Porcine Thyroid Transcription Factor 1 (TTF1) Quantitative Detection Kit (ELISA) Instructions for Use

Shanghai Hengdailao Trading Co., Ltd. is mainly engaged in the research and development and sales of laboratory equipment, immunology, molecular biology and conventional biochemical reagents. And agent sales of many well-known foreign brands, is committed to providing first-class scientific research reagents and perfect technical services for the vast number of universities, research institutes and enterprises. Welcome to inquire.
This kit can only be used for scientific research, not for medical diagnosis.

Porcine Thyroid Transcription Factor 1 (TTF1) Quantitative Detection Kit (ELISA)

user's Guide

【Porcine Thyroid Transcription Factor 1 (TTF1) Elisa Kit Kit Name】

Porcine Thyroid Transcription Factor 1 (TTF1) Quantitative Detection Kit (ELISA)

【Porcine Thyroid Transcription Factor 1 (TTF1) Elisa Kit Kit Usage】

Quantitative detection of thyroid transcription factor 1 (TTF1) in swine serum, plasma and related liquid samples.

[Principle of Porcine Thyroid Transcription Factor 1 (TTF1) Elisa kit detection principle]

This kit uses double-antibody two-step sandwich enzyme-linked immunosorbent assay (ELISA). Add the standard and the test sample to the pre-coated plate of porcine thyroid transcription factor 1 (TTF1) monoclonal antibody transparent enzyme label. After incubation for a sufficient time, wash to remove unbound components, and then add the enzyme label working solution After sufficient incubation time, wash to remove unbound components. Substrates A and B are added in sequence, and the substrate (TMB) is converted into a blue product catalyzed by horseradish peroxidase (HRP), which turns yellow under the action of an acid. The concentration of 1 (TTF1) is positively correlated. The OD value is measured at a wavelength of 450 nm. Based on the OD value of the standard and the sample, the content of porcine thyroid transcription factor 1 (TTF1) in the sample is calculated.

[Constitution of Porcine Thyroid Transcription Factor 1 (TTF1) Elisa Kit]

1

Enzyme coated plate

12 holes × 8

7

Developer A liquid

6mL

2

Standard

0.3mL × 6 tubes

8

Developer B liquid

6mL

3

20 times concentrated washing liquid

25mL

9

Stop solution

6mL

4

Sample diluent

6mL

10

Instructions

1 serving

5

Special diluent

6mL

11

Sealing film

2 sheets

6

Enzyme reagent

6mL

12

sealed bag

1

Remarks: The concentration of standard products (No. 1 → No. 6) is: 16, 8, 4, 2, 1, 0.5 pmol / L

[Reagents and equipment not required by the porcine thyroid transcription factor 1 (TTF1) Elisa kit]

1. 37 ℃ thermostat

2. Standard specification microplate reader

3. Precision pipettes and disposable tips

4. Distilled water

5. Disposable test tubes

6. Absorbent paper

【Procedures of Porcine Thyroid Transcription Factor 1 (TTF1) Elisa Kit】

1. Preparation: Remove the reagent kit from the refrigerator and re-equilibrate at room temperature for 30 minutes.

2. Mixing solution: dilute the 20-fold concentrated washing solution with distilled water to the original one.

3. Add standard products and samples to be tested: take a sufficient number of enzyme-coated plates and fix them to the frame. Set up standard wells, sample wells to be tested and blank control wells, record the positions of each well in the standard wells. Add 50μL of standard product; first add 10μL of the sample to be tested, then add 40μL of sample diluent (that is, the sample is diluted 5 times); the blank control well is not added.

4. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.

5. Wash the plate: discard the liquid, pat dry on the absorbent paper, fill each well with the washing liquid, let stand for 1min, shake off the washing liquid, pat dry on the absorbent paper, repeat the washing plate 4 times (you can also use the washing machine to press Instructions for washing the board).

6. Add enzyme-labeled working solution: add 50μL of enzyme-labeled working solution to each well, without adding blank control wells.

7. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.

8. Plate washing: Discard the liquid, pat dry on the absorbent paper, fill each hole with the washing liquid, let stand for 1min, shake off the washing liquid, pat dry on the absorbent paper, repeat the plate washing 4 times (you can also use the washing machine to press Instructions for washing the board).

9. Color development: add 50μL of developer A solution to each well, and then add 50μL of developer B solution. Mix with a plate mixer for 30s (or shake gently by hand for 30s), and avoid color development at 37 ℃ for 15min .

10. Termination: Remove the enzyme labeling plate and add 50μL of stop solution to each well to stop the reaction (the color changes from blue to yellow)

11. Determination: Zero the blank holes, and within 15 minutes after termination, measure the absorbance (OD value) of each well with a wavelength of 450 nm.

12. Calculation: According to the concentration of the standard product and the corresponding OD value, calculate the linear regression equation of the standard curve, and then calculate the corresponding sample concentration on the regression equation according to the OD value of the sample. You can also use various application software to Calculation. The final concentration is the actual measured concentration times the dilution factor.

[Pig Thyroid Transcription Factor 1 (TTF1) Elisa kit sample requirements]

1. The sample cannot contain sodium azide (NaN3) because sodium azide (NaN3) is an inhibitor of horseradish peroxidase (HRP).

2. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.

3. The sample should be fully centrifuged, without hemolysis and particles.

[Precautions for Porcine Thyroid Transcription Factor 1 (TTF1) Elisa Kit]

1. The experiment is carried out in strict accordance with the instructions, and the result of the experiment must be determined by the reading of the microplate reader.

2. If the enzyme-labeled coated board is not used up after opening, it should be put into a sealed bag and added with desiccant immediately.

3. It is recommended that all standards, samples and blank controls be tested in duplicate, and the average value is taken to reduce the experimental error.

4. Keep in mind that the sample has been diluted 5 times. The calculation result is multiplied by 5 to obtain the actual concentration of the sample.

5. The quantitative range of this kit is 0.5-16pmol / L, beyond this range, it is calculated by the extension of the standard curve, not as an accurate quantitative result, please dilute it with a special diluent to determine the accurate result (within the range of 0.5-16pmol / L ), Multiplied by the total dilution factor is the final concentration of the sample.

6. If the color is too light, the substrate incubation time can be extended properly.

7. In order to avoid cross-contamination, the tips, samples and blank controls should be replaced with a new one for each addition; the common components such as enzyme working solution, sample diluent and substrate should be cantilevered, and they should not touch the microwells. ; Do not reuse the sealing film.

8. The kits are used within the warranty period, and different batches of reagents should not be mixed.

9. Substrate B is sensitive to light and avoid prolonged exposure to light.

[Summary of operating procedures of porcine thyroid transcription factor 1 (TTF1) Elisa kit]

Prepare reagents, samples and standards


Add prepared samples and standards, and react at 37 ℃ for 30 minutes

Wash the plate 4 times, add the enzyme reagent, and react at 37 ℃ for 30 minutes

Wash the plate 4 times, add color developing solutions A and B, and develop at 37 ℃ for 15 minutes

Add stop solution

Read OD value within 15 minutes

Calculation

【Porcine thyroid transcription factor 1 (TTF1) Elisa kit detection range】

0.5pmol / L – 16 pmol/L

【Specification of Porcine Thyroid Transcription Factor 1 (TTF1) Elisa Kit】

96 servings / box

【Storage of Porcine Thyroid Transcription Factor 1 (TTF1) Elisa Kit】

Store at 2-8 ℃, protected from light and moisture.

【Porcine Thyroid Transcription Factor 1 (TTF1) Elisa Kit Validity Period】

6 months

Chest Of Drawers

Dressers have many different styles and functionalities. However, the most popular are all dressers, chest dressers, media chest dressers, and dressers with mirrors. All dressers and chest dressers are the most traditional type of this furniture and provides an ample amount of space to store your clothes and belongings.

Chest Of Drawer

On the other hand, if you are looking to maximize the available space in your room, media chest dressers and dressers with mirrors will provide additional storage. Media chest dressers are designed to provide plenty of space for a TV on top and may include a cubby area that can hold your cable box or other device. If you choose one with this feature, they also include a hole in the back to allow wiring to easily connect to your wall. In order to prevent tipping, we recommend that the dimension of the TV should not exceed the width of the dresser.

Chest Of Drawers,Wooden Chest Of Drawers,Mirrored Chest Of Drawers,Solid Wood Chest Of Drawers

Jinan Tri-Tiger Technology Development Co., Ltd , https://www.jinanfurniture.com